Weighbridges anticipate a central part in various affiliations, like systems, of making, and assembling, where unequivocal weight evaluation is head. At the central sign of a weighbridge structure lies the store cell, a basic part that draws in clear weight interest. A load cell is a transducer that changes overpower or stack into an electrical sign, considering wary weight evaluation. It is sensible to the significant clear piece of a weighbridge structure, changing the power applied by a store into an electrical result that can be considered and unwound.
Load cells are unequivocally planned under the weighbridge stage to assist with focusing on the load. As vehicles or articles drive onto the weighbridge, the load cells see and check the power applied by the weight. This evaluation is then lively about an electrical sign talking with the applied load, which is coordinated overall to give a mindful weight appraisal.
We make two types of Load Cells,
Technical Parameter | |
---|---|
A/D Module Resolution | 100000 |
Data refresh frequency | 50HZ |
Communication baud rate | 9600BPS |
Total Error | ±0.02%F.S |
Creep Error (30 min) | ±0.02%F.S |
Temperature effect sensitivity | ±0.02% F.S/10°c |
Temperature range | -30~+70°c |
Zero balance | ±0.1%F.S |
Safe overload | 150%F.S |
Protection class | IP68 |
Recommended input voltage | 9~12VDC |
Max input voltage | 20VDC |
Max signal transmission distance voltage | 1200m |
Specification | |
---|---|
Rated capacity: 5ton to 50ton | Operating temperature range: -30 to +70°c |
Rated output:2.0±0.002mv/v | Maximum safe overload 150% OF R.C |
Combined error:±0.03% F.S | Ultimate safe overload;200% OF R.C |
Non-repeatability ±0.02% F.S | Recommended Excitation 10 to 12V DC |
Non-linearity ±0.02% F.S | Maximum Excitation 15V DC |
Hysteresis error: ±0.02% F.S | Environment protection: IP68 |
Zero balance: ±1% F.S | Input impedance: 750±10Ω |
Creep error(30minutes): ±0.02% F.S | Output impedance: 702±3Ω 703±5Ω(cable≥15m) |
Temperature effect on zero: ±0.02% F.S | Insulation resistance at 50V DC: ≥ 5000MΩ |
Temperature effect on output: ±0.02% F.S | Material: nickel-plated alloy steel; |
Compensated temperature range: -10 to +40°c | Cable length: 5.2meter(5t); 8meter(10t); 10meter(15t); 10/12meter(20t); 12/16meter(25t~50t), diameter 6mm |
Evident weight assessment is overseen in experiences that rely upon weighbridges for various purposes, including freight the board, stock control, and consistency with guidelines. Load Cells in Weighbridges ensure the precision and attestation of weight evaluations, allowing connections to go with informed decisions and contemplating unequivocal data. Changed load cells give certain and clear results, diminishing goofs and keeping cash-related calamities by stirring up weight evaluations.
Load Cells in Weighbridges the supporting weighbridge structures, attracting sure weight appraisal for various undertakings. By changing the power a load applies into an electrical sign, load cells have a focal impact in ensuring careful and solid weight readings. Understanding the different sorts of load cells and their show factors helps the relationship in picking the most fitting load cells for their weighbridge applications, all through a wide time managing epic shrewd nature and working with informed bearing.