Load Cell for Weighbridge Supplier in India

Load Cell for Weighbridge, Load Cell for Weighbridge Supplier, Load Cell for Weighbridge Suppliers, Load Cell for Weighbridge Suppliers in India, Load Cell for Weighbridge Manufacturer, Load Cell for Weighbridge Supplier, Load Cell for Weighbridge Supplier in India, Load Cell for Weighbridge in Gujarat, Load Cell for Weighbridge Supplier in Gujarat, Load Cell for Weighbridge Manufacturer in Gujarat, Load Cell for Weighbridge Manufacturers, Load Cell for Weighbridge Suppliers, Load Cell for Weighbridge Manufacturers in India, Load Cell for Weighbridge Suppliers in India, Load Cell for Weighbridge Manufacturers in Gujarat, Load Cell for Weighbridge Suppliers in Gujarat, Load Cell for Weighbridge Manufacturer, Load Cell for Weighbridge Supplier, Load Cell for Weighbridge Manufacturer in India, Load Cell for Weighbridge Supplier in India

Load Cell for Weighbridge Supplier in India

Matrix Weighing Systems Pvt. Ltd. is a trustworthy Load Cell for Weighbridge Supplier in India. We were coordinated in 2007 with a clear vision to offer the most solid and financially savvy responses in the gauging business.

A load cell is a sort of transducer that is utilized to change mechanical power into a purposeful electrical yield, anything which should be weighed evidently uses a load cell to do along these lines. Load cells come in various shapes and sizes with the target that they can be added to various mechanical gathering and measuring contraptions.

We produce two types of Load Cells,

  • Digital Load Cell

    • Technical Parameter
      A/D Module Resolution 100000
      Data refresh frequency 50HZ
      Communication baud rate 9600BPS
      Total Error ±0.02%F.S
      Creep Error (30 min) ±0.02%F.S
      Temperature effect sensitivity ±0.02% F.S/10°c
      Temperature range -30~+70°c
      Zero balance ±0.1%F.S
      Safe overload 150%F.S
      Protection class IP68
      Recommended input voltage 9~12VDC
      Max input voltage 20VDC
      Max signal transmission distance voltage 1200m
  • Analog Load Cell

    • Specification
      Rated capacity: 5ton to 50ton Operating temperature range: -30 to +70°c
      Rated output:2.0±0.002mv/v Maximum safe overload 150% OF R.C
      Combined error:±0.03% F.S Ultimate safe overload;200% OF R.C
      Non-repeatability ±0.02% F.S Recommended Excitation 10 to 12V DC
      Non-linearity ±0.02% F.S Maximum Excitation 15V DC
      Hysteresis error: ±0.02% F.S Environment protection: IP68
      Zero balance: ±1% F.S Input impedance: 750±10Ω
      Creep error(30minutes): ±0.02% F.S Output impedance: 702±3Ω 703±5Ω(cable≥15m)
      Temperature effect on zero: ±0.02% F.S Insulation resistance at 50V DC: ≥ 5000MΩ
      Temperature effect on output: ±0.02% F.S Material: nickel-plated alloy steel;
      Compensated temperature range: -10 to +40°c Cable length: 5.2meter(5t); 8meter(10t); 10meter(15t);
      10/12meter(20t); 12/16meter(25t~50t), diameter 6mm

      Features:

      • Capacity: 5t to 50t
      • Steel ball loading, strong restoration ability
      • Easy complete installation, high weighing accuracy
      • OIML C3 certificate
      • Alloy Steel

For any Enquiry, You can go on our Enquiry Page.

For more details, you can Contact Us.